Superior Dej purification tshuab rau qhov ncauj / plab hnyuv Endoscopy / Disinfection Center Dej Supply System

  • Hauj lwm
  • Kev Specifications

Cov yam ntxwv ntawm lub kaw lus >

● Cov dej zoo ntawm cov khoom ua raws li "WS 507-2016" Kev Siv Tshuab Ntxuav thiab Tua Kab Mob ntawm Cov Khoom Siv Endoscope Mos, ua raws li tus qauv dej ntxuav "GB5749-2006".

● Ua haujlwm tsis siv neeg, kuaj xyuas tus kheej thaum pib, tiv thaiv dej nyoos hauv qab siab, kaw tsis siv neeg thaum dej siab dhau/dej puv.

● Siv Cortex-A8 processor 7-nti txiv neej-tshuab interface thiab microcomputer tswj, tag nrho cov txheej txheem real-time animation simulation zaub, real-time saib xyuas ntawm cov kais dej conductivity, dej ntshiab conductivity Thiab lwm yam dej zoo mob, nrog parameter hloov kho thiab cov ntaub ntawv cia thiab luam ntawv functions.

● Lub kaw lus teeb tsa tus neeg siv tus password nkag mus, uas tuaj yeem ntxiv thiab hloov kho lub npe neeg siv thiab tus password kom tiv thaiv Tiv thaiv kev ua haujlwm tsis raug cai thiab kev hloov pauv cov ntaub ntawv.

● Lub kaw lus khiav lub sijhawm sib sau ua ke thiab lub sijhawm tiag tiag, lub sijhawm hloov pauv ntawm lub kaw lus tuaj yeem, hloov lub sijhawm tshuab thiab lub lim tiam cov neeg siv teeb tsa dawb do.

● Lub tswb ceeb toom txog kev ua tsis tiav ntawm lub kaw lus thiab lub tswb ceeb toom hloov khoom siv, lub qhov rai tso saib lub tswb ceeb toom hauv lub sijhawm tiag tiag.

● Lub kaw lus yog tsim los ntawm kev tsim cov dej ntws tsis siv neeg thiab muaj kev ua haujlwm sab hauv, ua kom lub neej ua haujlwm ntawm RO ntev dua.

● Cov khoom siv txais yuav cov khoom siv sab saum toj los ntawm txawv teb chaws thiab hauv tsev kom ua rau lub kaw lus khiav tau zoo dua thiab ruaj khov kom ntseeg tau tias cov dej ntws zoo.

● Lub kaw lus tuaj yeem hloov kho qhov kev ua haujlwm saib xyuas chaw deb, uas tuaj yeem ua tiav kev ua haujlwm deb thiab kev ua yeeb yam simulation real-time saib xyuas, kev tso saib cov ntaub ntawv thiab khaws cia, kev hloov kho parameter, lub tswb nrov, kev luam ntawv cov ntaub ntawv thiab lwm yam haujlwm.

● PLC, LCD kov npo, lub koob yees duab saib xyuas thiab lwm yam thev naus laus zis siv tau los ua kom pom tseeb tag nrho cov zaub mov tsis siv neeg, ua haujlwm, thiab tswj hwm. Lub khoos phis tawj sau cov kev ua haujlwm ntawm cov khoom siv thiab luam tawm daim ntawv qhia. Daim ntawv qhia no yooj yim rau kev tshuaj xyuas cov ntaub ntawv sib raug zoo ntawm cov dej sim zoo thiab cov txiaj ntsig ntawm kev sim.

● Qhov siv tau: lub qhov ncauj hauv tsev kho mob, lub rooj zaum kho hniav thiab lwm yam khoom siv txhawb nqa, lub cuab yeej kho mob gastroenteroscope lub plawv-rau-lub plawv Ntxuav thiab tua kab mob ntawm cov khoom siv, cov tais diav, thiab cov khoom.


Cov dej uas muaj feem cuam tshuam yuav cuam tshuam rau qhov zoo ntawm cov dej ntshiab thiab lub neej ntawm cov khoom siv, thaum cov dej TDS ≥ 500 ppm, nws raug pom zoo kom siv cov khoom siv ua ntej ob npaug lossis cov txheej txheem osmosis ob theem rov qab.

Kev tsis

hom nab npawb MK-XD500/1000/1500/2000L-RV, MK-XD500/1000/1500/2000L-2RD
txheej txheem ntws Rov qab osmosis + UV + ozone / ob theem rov qab osmosis + UV + ozone
Kev tsim dej 500/1000/1500/2000L/H
Cov khoom siv dej zoo Qib rov qab osmosis conductivity≤10 us / cm (25 ℃), II rov qab osmosis conductivity N / A, ≤5 us / cm (25 ° C), Cov khoom me me <1 / ml, Tus lej khoom me me (≤0.22 um) <1 / ml, Cov kab mob <10 cfu / ml

system yuav tsum muaj

Yuav tsum muaj dej Municipal kais dej
Inlet siab 0.2-0.4Mpa
hluav taws xob xav tau 380V/AC 50Hz
Tus nqi ua tiav 2-5KW
kub siv 5-45 ℃
Teeb Chaw Ib Zaug Qhov cua, noo noo-pov thawj, tiv thaiv corrosion